Reverse Osmosis Plants
Reverse Osmosis works by using a
The desalinated water that is demineralized or deionized, is called permeate (or product) water. The water stream that carries the concentrated contaminants that did not pass through the RO membrane is called the reject (or concentrate)
One of the common water contaminants addressed by the pre-treatment stage is suspended solids. Fine particles of dirt and other matter floating in suspension within the feed water. These particles are not dissolved into the water and have to be physically removed via filtration.
Reverse Osmosis membranes, the core component of the RO plant are not designed to remove such suspended particles and will foul rapidly if left to do so. As such adequate filtration is required prior to any Reverse Osmosis System in order to achieve proper system operation and avoid premature fouling of the membranes.
Different sources of feed water will typically have different levels of suspended solids. Surface waters such as rivers and dams tend to have the highest levels, as they catch water running across the earth which is typically heavily laden with dirt and other solids. While bore water extracted from deep within the earth has much lower levels as the water has been filtered by the rocks through which it passes prior to collection. As such these two feed
Skid Mounted RO
One of the first steps in designing a suitable
Hub 4 Water RO units are designed and
Hub 4 Water skid mounted RO plant utilise either 2.5”, 4.0” or 8.0” Dow Filmtec or Hydranautics reverse osmosis membranes suitable for the application and we carry a full range of spares and consumables
Our RO plant is designed to maximise water efficiency and minimise waste. The recovery rate, that is the ratio of feedwater recovered as
A typical RO skid will include only the components of the RO unit, whilst both the Pre and
Post Treatment
Following the RO
It is quite common, but not necessary for the RO water to go through one
5-35kl/day – 50-500/klDay Reverse Osmosis Plant
Product Flow Rate @ | 5-35m3/day 50-500kl/day |
System Pressure | 2000kPa max |
Water supply Brackish | <2000TDS |
Low Pressure Pump | Optional |
High Pressure Pump | 304-316SS (dependent on water supply) |
VSD |
LP and HP pumps |
Control |
Microprocessor/ PLC |
Control Function |
Automatic |
Protection |
Low Pressure, motor overload |
Protection optional |
High Pressure, antiscalant fault |
Antiscalant dosing |
Included |
Pre filtration |
5/ 1micron cartridge filters |
Media Filtration |
Optional |
Instrumentation |
Mag flow meters and Pressure transducers or rotameters and pressure gauges |
Low Pressure Piping |
uPVC |
High pressure piping |
uPVC or 316SS (depending on pressure) |
Clean in Place |
included |
Membranes |
Brackish Water |
Skid mounted and containerised options available
Remote monitoring
Spares and consumables
- RO membranes
- Antiscalants
- CIP Cleaners
- Disinfectants
- Membrane analysis
- Pumps
- Chemical dosing equipment
- Servicing and maintenance
- Controls and Instrumentation
- Valves and piping/fittings